Washer-disinfectors - Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes (ISO 15883-4:2018)
This document specifies the particular requirements, including performance criteria for washer-disinfectors (WD) that are intended to be used for cleaning and chemical disinfection of thermolabile endoscopes. This document also specifies the performance requirements for the cleaning and disinfection of the washer-disinfector and its components and accessories which can be required to achieve the necessary performance criteria. The methods, instrumentation and instructions required for type testing, works testing, validation (installation, operational and performance qualification on first installation), routine control and monitoring, and requalification of WD periodically and after essential repairs, are also specified. NOTE 1 In addition, Annex A gives guidance on an appropriate division of responsibility for the range of activities covered by this document. NOTE 2 WD complying with this document can also be used for cleaning and chemical disinfection of other thermolabile re-usable medical devices for which the device manufacturer has recommended and validated this method of disinfection. WD complying with the requirements of this document are not intended for cleaning and disinfection of medical devices, including endoscopic accessories, which are heat stable and can be disinfected or sterilized by thermal methods (see ISO 15883-1:2006+Amd 1:2014, 4.1.5). The specified performance requirements of this document do not ensure the inactivation or removal of the causative agent(s) (prion protein) of transmissible spongiform encephalopathies. NOTE 3 If it is considered that prion protein might be present, particular care is needed in the choice of cleaning agents and disinfectants to ensure that the chemicals used do not react with the prion protein and/or other protein in a manner that can inhibit its removal or inactivation from the load or washer-disinfector. NOTE 4 This document can be used by prospective purchasers and manufacturers as the basis of agreement on the specification of the WD, manufacturers of endoscopes, cleaning products, and disinfecting products.
- Originator
- INB
- Published
- 2019-08-01
- ICS
- 11.080.10
SN EN ISO 15883-4:2019
Reinigungs-Desinfektionsgeräte - Teil 4: Anforderungen und Prüfverfahren für Reinigungs-Desinfektionsgeräte mit chemischer Desinfektion für thermolabile Endoskope (ISO 15883-4:2018)
Washer-disinfectors - Part 4: Requirements and tests for washer-disinfectors employing chemical disinfection for thermolabile endoscopes (ISO 15883-4:2018)
This document specifies the particular requirements, including performance criteria for washer-disinfectors (WD) that are intended to be used for cleaning and chemical disinfection of thermolabile endoscopes. This document also specifies the performance requirements for the cleaning and disinfection of the washer-disinfector and its components and accessories which can be required to achieve the necessary performance criteria. The methods, instrumentation and instructions required for type testing, works testing, validation (installation, operational and performance qualification on first installation), routine control and monitoring, and requalification of WD periodically and after essential repairs, are also specified. NOTE 1 In addition, Annex A gives guidance on an appropriate division of responsibility for the range of activities covered by this document. NOTE 2 WD complying with this document can also be used for cleaning and chemical disinfection of other thermolabile re-usable medical devices for which the device manufacturer has recommended and validated this method of disinfection. WD complying with the requirements of this document are not intended for cleaning and disinfection of medical devices, including endoscopic accessories, which are heat stable and can be disinfected or sterilized by thermal methods (see ISO 15883-1:2006+Amd 1:2014, 4.1.5). The specified performance requirements of this document do not ensure the inactivation or removal of the causative agent(s) (prion protein) of transmissible spongiform encephalopathies. NOTE 3 If it is considered that prion protein might be present, particular care is needed in the choice of cleaning agents and disinfectants to ensure that the chemicals used do not react with the prion protein and/or other protein in a manner that can inhibit its removal or inactivation from the load or washer-disinfector. NOTE 4 This document can be used by prospective purchasers and manufacturers as the basis of agreement on the specification of the WD, manufacturers of endoscopes, cleaning products, and disinfecting products.
Content pages for this standard
guide
Overview of SN EN ISO 15883-4:2019 for Washer-Disinfectors
Explore SN EN ISO 15883-4:2019, outlining requirements for washer-disinfectors for thermolabile endoscopes in healthcare technology.
Understanding the ISO 15883-4:2018 Standard for Washer-Disinfectors
Explore the ISO 15883-4:2018 standard for washer-disinfectors and learn about its compliance requirements in the healthcare industry.
Related standards
SN EN ISO 5832-1:2024
Implants for surgery - Metallic materials - Part 1: Wrought stainless steel (ISO 5832-1:2024, Corrected version 2025-06)
SN EN ISO 15883-1:2025
Washer-disinfectors - Part 1: General requirements, terms and definitions and tests (ISO 15883-1:2024)
SN EN ISO 10993-1:2021
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process (ISO 10993-1:2018, including corrected version 2018-10)
SN EN ISO 11607-2:2020
Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes (ISO 11607-2:2019)
SN EN 285+A1:2021
Sterilization - Steam sterilizers - Large sterilizers
SN EN ISO 22367:2020
Medical laboratories - Application of risk management to medical laboratories (ISO 22367:2020)